EPP2000HR NIR2

Spectrometer by Edinburgh Instruments

Note: Your Quotation Request will be directed to Edinburgh Instruments.

The EPP2000HR NIR2 from Edinburgh Instruments is a Fiber-Optic Spectrometer that operates at a wavelength of 900 nm - 1075 nm. It has a 2048-pixel CCD detector that provides a detector range of 200 nm - 1200 nm. This NIR spectrometer has a pixel size of 14 µm x 200 µm and a diffraction grating of 1200 gr/mm (holographic & ruled) with a grating range of 175 nm. It has a dynamic range of 2000:1 with 6 decades and an f-number of 4. This SymX-Czerny-Turner spectrometer is available in different slit size options such as 7 µm (0.09 nm resolution), 14 µm (0.17 nm resolution), and 25 µm (0.26 nm resolution). It has integrated & high-pass order sorting filters with a 14-bit or 16-bit digitizer.

The EPP2000HR NIR2 has a signal-to-noise ratio of 1000:1 (CCD) and can be controlled via USB-2 or EPP parallel interfaces. It has a detector integration time of 1 ms - 65 s and stray light of up to 0.1% (at 435 nm) & up to 0.05% (at 600 nm). This spectrometer uses the SpectraWiz program & apps and can be operated using Win9x/WinXP/Vista/Win7 operating systems. It also supports LabView, Excel+VBA, and Delphi software. This spectrometer requires a DC supply voltage of 5 V and consumes 100 mA of current. It is available in a benchtop package that measures 44 mm x 94 mm x 150 mm and is ideal for wavelength monitoring and characterization for tunable lasers/LEDs & other sources such as elemental emissions from plasma, and laser-induced breakdown spectroscopy applications.

Product Specifications

View similar products

Product Details

  • Part Number
    EPP2000HR NIR2
  • Manufacturer
    Edinburgh Instruments
  • Description
    900 nm - 1075 nm, Fiber Optic Spectrometer for LIBS Applications

Connections & Interface

  • Fiber optic connector
    SMA 905
  • Interface
    USB 2.0

General Parameters

  • Measuring Techniques
    NIR Spectroscopy
  • Spectrometer Type
    Benchtop, Portable
  • Wavelength Range
    900 to 1075 nm
  • Spectral Resolution
    Slit Resolution: 0.26, 0.17, 0.09 nm
  • Spectrum Band
    UV, VIS, NIR
  • Integration Time
    1 milliseconds to 65 seconds
  • Stray Light :
    1% @435 nm, .05% @600 nm
  • Slitwidth
    Slit Size: 7, 14, 25, 50, 100, 200 µm
  • Aperture(f-number)
    F/4
  • Detector Array
    2048 pixel CCD
  • Detector Range
    200 to 1200 nm
  • Dynamic Range
    2000:1 with 6 decades
  • Pixels Size
    14 x 200 um
  • Grating :
    1200 g/mm
  • Noise Ratio
    1000:1 CCD
  • Operating System
    Win9x/WinXP/Vista/Win7
  • Note
    Grating Range: 175 nm

Physical Properties

  • Dimension
    44 x 94 x 150 mm

Technical Documents

Click to view more product details on manufacturer's website
Request a Quote